The following issues have been fixed since Citrix Virtual Apps and Desktops 7 1912 LTSR CU8:

Citrix Provisioning

Citrix Provisioning 1912 CU9 documentation provides specific information about the updates in this release.

Delivery Controller

  • Create\Update machine catalog task fails in Availability Zone B but works fine for Availability Zone A and C because a volume service instance could not be launched in your cloud connection. Run the below command to update the Site Database table to use the new VolumeWorkerTemplate on the SQL server.

    UPDATE HostingUnitServiceSchema.VolumeServiceConfigurationBaseTemplate SET TemplateId = ‘ami-09b42976632b27e9b’ WHERE RegionName = ‘ap-southeast-2’

    Note: Availability Zone may be different for different customers.

    [CVADHELP-24094]

  • Updates on the MonitorData.ResourceUtilization table in the monitoring database are delayed. [CVADHELP-22724]

Linux Virtual Delivery Agent

Linux Virtual Delivery Agent 1912 CU9 documentation contains no fixed issues.

Metainstaller

  • Upload authorization: If you plan to upload diagnostic collections to Citrix, you must have a Citrix or Citrix Cloud account. (These are the credentials you use to access Citrix downloads or access the Citrix Cloud Control Center.) After your account credentials are validated, a token is issued. If you authenticate with a Citrix account or a Citrix Cloud account, click a link to access Citrix Cloud using HTTPS with your default browser. After you enter your Citrix Cloud credentials, the token is displayed. Copy the token and then paste it into Scout. You can then continue in the Scout wizard. The token is stored locally on the machine where you’re running Scout. To enable use of that token the next time you run Collect or Trace & Reproduce, select the Store token and skip this step in the future check box. You must reauthorize each time you select Schedule on the Scout opening page. You cannot use a stored token when creating or changing a schedule. [CVADHELP-24415]

Profile Management

Profile Management 1912 CU9 documentation provides specific information about the updates in this release.

Session Recording

Session Recording 1912 CU9 documentation provides specific information about the updates in this release.

StoreFront

StoreFront 1912 CU9 documentation provides specific information about the updates in this release.

Universal Print Server

Printing

  • Printers connected to Universal Print Server might not appear in sessions for printing. The issue occurs when the httpd.conf file in Universal Print Server is updated. [CVADHELP-21139]

  • When you use VDA version 1912 CU5 and OS version 2012 R2, various print jobs are failing from the production Citrix UPS print server with the following error message: CCgpStream::Open: WaitForMultipleObjects time out. InternalUpcRemoteOpenStream: Failed to Open Stream. Abort Job. [CVADHELP-22354]

VDA for single-session OS

Printing

  • Attempt to print a file through local printers using Citrix Workspace app for Mac running macOS Sonoma might fail with the following error message:

    Error: Printer not activated. Error code -41

    [CVADHELP-23839]

  • When you restart a VDA with the Universal Print Server policies enabled, load balancing for Universal Print Servers might fail to start. [CVADHELP-23714]

  • Local printers might not get redirected to the session during the first launch. However, the local printers are redirected during subsequent launches. [CVADHELP-23334]

Session/Connection

  • CtxSvcHost (CtxSmartCardSvc) might exit unexpectedly when you log off from the VDA. [CVADHELP-23172]

  • The Microsoft Teams redirection key MSTeamsRedirSupport under the registry HKEY_CURRENT_USER\SOFTWARE\Citrix\HDXMediaStream might be missing when you reconnect to a user device through a user session. The issue occurs when an RDP session is still existing. [CVADHELP-19993]

  • If printers or print servers are unreachable, session logon and logoff might take a lot of time to respond. [CVADHELP-23637]

  • The WebSocketService.exe process fails to start after a VDA reboot on the leap day. [CVADHELP-24771]

  • Microsoft Teams 2.1 is not optimized by default on the VDA. [CVADHELP-24767]

VDA for multi-session OS

Printing

  • Attempt to print a file through local printers using Citrix Workspace app for Mac running macOS Sonoma might fail with the following error message:

    Error: Printer not activated. Error code -41

    [CVADHELP-23839]

  • When you restart a VDA with the Universal Print Server policies enabled, load balancing for Universal Print Servers might fail to start. [CVADHELP-23714]

  • Local printers might not get redirected to the session during the first launch. However, the local printers are redirected during subsequent launches. [CVADHELP-23334]

Session/Connection

  • If the Session Recording agent is not installed on the VDA and you run Get-BrokerSessionRecordingStatus, Start-BrokerSessionRecording, and Stop-BrokerSessionRecording PowerShell commands, then the VDA deregisters and registers again with the Delivery Controller within a few seconds. This action has no impact on the existing sessions. If the Session Recording agent is installed on the VDA, the PowerShell commands work without issue. [CVADHELP-23686]

  • The WebSocketService.exe process might consume more memory than expected on the VDAs. [CVADHELP-23870]

  • CtxSvcHost (CtxSmartCardSvc) might exit unexpectedly when you log off from the VDA. [CVADHELP-23172]

  • The WebSocketService.exe process fails to start after a VDA reboot on the leap day. [CVADHELP-24771]

System Exceptions

  • When you upgrade a VDA from 1912 LTSR CU5 to CU6, a fatal exception occurs on Wdica.sys, and a blue screen with a bug check code, 0x000000CE is displayed. [CVADHELP-22365]